Products Description
High-Pressure Furnace with Dual Temperature Zones Capable of Operating at 1100°C
Technical Parameters
Model | XW-DSP-1200℃-SRI | XW-DSP-1200℃-SRI |
Power | 3.5 KW | 4 KW |
Furnace tube size(mm) | Dia 60(OD) X1200 | Dia 120(OD) X1200 |
Dimension | 580X370X1050 | 600X440X1100 |
Power supply voltage | 220V | |
Phase number | Single-phase | |
Temperature control mode | 一.Yudian temperature control | |
30 sections can only use PID temperature regulation. | ||
二.FP93 temperature control (from Japan) | ||
(Replace imported instruments, for an additional fee) | ||
1,40 section program temperature control can be divided into 4,2,1 group program, | ||
if the program is divided into four groups, each program segment 10, | ||
2,6 group PID control, low, medium and high temperature can each with a set of PID, | ||
such that each segment is capable of controlling the temperature is very accurate. | ||
Control accuracy | +/- 1 ℃ | |
Tube rotation speed | Stepless variable speed motor, speed can be adjustable between (1-25 turn / min) | |
Motor rotation power | 40W | |
Furnace tilt angle range | 0-30 degrees | |
Electric lift support frame power | 40W | |
Trigger | Phase-shift trigger | |
SCR | 106 / 16E Germany Simon Kang | |
Max temperature | 1200 ℃ | |
Rated temperature | 1100 ℃ | |
Heating rate | ≤30 ℃/ Min (Available upon request modification) | |
Recommended heating rate | ≤20℃/ Min | |
Heating length | 400mm | |
Thermocouple Type | K type | |
Surrounding surface temperature | ≤45℃ | |
Security System | With the furnace air switch and fuse, when the current exceeds the rated current, | |
it will automatically jump open, effective protection electric stove. | ||
Switch protection system | The furnace trip switch is installed, when the lid open relay will automatically | |
cut off the main power supply, effectively ensure the safety of users. |