Products Description
1 The XW-BTS-15V6A battery tester device is an eight-channel battery analyzer for analyzing polymer and cylindrical batteries from 12 mA to 6000 mA up to 15V.
2 This battery test system provides most applications in the battery testing field, such as electrode material research, battery performance testing, small scale battery chemistry, capacity grading, battery pack testing, etc.
3This battery pack test system is mainly used for laptop battery pack performance testing.
Technical Parameters
Model | Battery pack tester XW-BTS-15V6A | |
Warranty | One Year limited warranty with lifetime support | |
Source voltage | AC110V-220V±10% Customized, 50/60HZ | |
Input impedance | ≥1MΩ | |
Input power | 1088W | |
Channel | Constant current source and voltage source adopt | |
characteristics | double closed loop independent structure | |
Channel control mode | Independent control | |
Voltage range | Charge : 3mV-15V Discharge : 2.5V-15V | |
per channel | Accuracy : ±0.1% | |
Current range | Charge : 12mA-6A Discharge : 12mA-6A | |
per channel | Accuracy : ±0.1% | |
Output power per channel | 200W | |
Time | Current response time | 0-6A : 20ms |
Step time range | 1s-365*24h,Time format : 00:00:00(H:Min:S) | |
Record condition | TimeΔt :1-60000s VoltageΔU : 40mV-20V | |
CurrentΔI : 20mA-10A | ||
Charging mode | Constant current charge,constant voltage charge, | |
constant current and voltage charge | ||
Discharging mode | Constant current discharge,constant power discharge | |
Conditions of constraint | Time, voltage, current, capacity | |
Cycle | Cycle range | 1-65535 times |
Steps pur cycle | 254 | |
Protection | Power-down data protection,off-line test function and Safety condition setting protection | |
Voice | ≤85dB | |
Communication interface | Serial ports | |
Channel number per unit | 8 | |
Dimension(L*W*H) | 485*508*263mm | |
Working temperature/humidity | -10-40℃ ≤70%RH |