Products Description
- Basic Composition
The system primarily consists of a computer, a communication interface, and a battery formation cabinet. The battery formation cabinet includes a plate body equipped with fixtures, a constant current and constant voltage power supply, a microcontroller, and a control panel.
- Main Performance
- Channel Capacity: The system features a total of 800 channels.
- Control Mode: Operates under whole machine control.
- Charging Modes: Supports both constant current and constant voltage charging.
- Charging Termination: Charging is terminated based on time.
- Power Supply: Each battery is equipped with an independent constant current and constant voltage source, ensuring that circuits do not interfere with each other. The system utilizes PWM charging for energy efficiency, significantly reducing heat generation and power consumption.
- Protection Features: Includes voltage upper limit protection for each battery to ensure safe charging up to the required voltage.
- Settings Adjustment: Charging current is centrally managed and can be adjusted via computer software or through keyboard operations.
- Process Configuration: The system allows for the setting of up to 20 step parameters via the host computer, with offline charging and other functionalities accessible through keyboard operations.
- Power Failure Protection: Equipped with a power-down protection feature that allows the system to resume the original workflow after power restoration.
- Voltage Screening: Capable of screening low-voltage cells post-charging.
Technical Parameters
3. Main technical parameters | |
Channels No. | 800 |
Workflow control method | Whole Cabin control (Single-point constant current, constant voltage mode) |
Charging model | Charging energy-saving mode: constant current, constant voltage charging |
Charging cut-off conditions | Time |
Current range | Charge 3mA-1A, resolution 1mA |
Current accuracy | ±0.1%RD |
Voltage measurement | 0~4999mV |
Time Set Range | 0~999 minutes can be set arbitrarily, the time unit is min |
Time accuracy | ≤±0.1% |
Clamp type | Cylindrical four-wire method quick push clamp type (with bracket) |
Supported battery types | Cylindrical Cell |
Clamp height adjustable range | Cylindrical Cell |
Working power | AC220V±10%,50HZ,Power consumption≤5KW |
Communication method | RS232,Baud rate4800 |
Equiment shape reference size (mm) | 1650 (L)×500(W)×1914 (H) (For reference only, the actual equipment shall prevail) |
Working environment | Temperature: 0-40℃, related temperature≤85% |
Full load operating current | Phase line up to 30A |
Equipment Weight | About 200kg |
4. CP System main configuration requirements
Minimum configuration of computer system: CPU above P4, memory above 2G, hard disk space above 200G, EGA/VGA color display, one CD-ROM, one mouse, MicrosoftTM Windows XP or above operating system, one available RS232 serial communication port, Windows support printer. The computer system need prepare by user, and the number of microcomputer systems is determined according to actual needs