Xiaowei

5V5A Lithium ion Battery Testing Equipment

Battery Process

More Custom Items

5V5A Lithium ion Battery Testing Equipment

Item No.: XW-CT-9004-5V5A-NA
Application: Lithium ion Battery Testing Equipment is used for pouch cell, cylinder cell, coin cell parameter testing,  it can test voltage, cycle life, capacitry and resistance.
Order(MOQ): 1 set;
Payment: T/T, Western Union, Paypal, L/C;
Product Origin: China;
Lead Time: 15days;
Note: XIAOWEI factory supports OEM.

 Products Description 

GSM Pulse, Cyclic Voltammetry, Rate, Statistic capacity, Cycle life, constant current, constant power, constant resistance, constant voltage,voltage Scan (cyclic Voltammetry),Waveform import, Arithmetic Functions,1Khz AC impedance, BTS Series, Channel No., Rack Color, Measuring Range, Net With Reverse-connecting Protection.

The New 9 series battery tester has more bigger testing speed and more higher accuracy.

 Technical Parameters 

Project indexParameter index
AC Input Power220/110V±10%/50Hz/60Hz
ResolutionAD:16bit;DA:16bit
Impedance Input≥500MΩ
Input Power250W
Channel FeaturesConstant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure
Channel Control ModeIndependent Control
VoltagePer Channel Voltage Range0.7V~5V
Lowest discharge voltage0.7V
Accuracy± 0.02%  of  FS
Stability±0.005% of  FS
CurrentMulti RangeRang1:   0.1uA—150uA    ± 30nA
Rang2: 150uA—5mA     ± 1uA
Rang3: 5mA—150mA    ± 30uA
Rang4:   150mA—5A    ± 1mA
Accuracy± 0.02%  of  FS
Stability±0.005% of  FS
PowerPer Channel Max. Output Power25W
Stability± 0.01%  of  FS
TimeCurrent Rise TimeThe Current gets to (10%-90%) Hardware Rise Time is 100μs
Step Time RangeSingle Step Time Rang>=10ms
Data RecordingRecord ConditionLower sampling time: >=1ms
Lower sampling Voltage:>= 1mV
Lower sampling Current: :>= 100nA
Record Frequency1000Hz
ChargeCharge ModeConstant Current Charge,Constant Voltage Charge,
Constant Current and Constant Voltage Charge,Constant Power Charge
End ConditonVoltage,Current,Relative Time,Capacity
DischargeDischarge ModeConstant Current Discharge,Constant power Discharge,
Constant  resistance  discharge,
End ConditionCurrent,Voltage,Relative Time,Capacity,
Pulse ModelChargeConstant Current Model;Constant Power Model
DischargeConstant Current Model;Constant Power Model
Min Pulse Width400μs
Pulse NumberSingle Pulse Step Support 16 different Pulse
Charge r To DischargeOne Pulse Step Can Support Continuous Charge And Discharge Change
End ConditionVoltage,Relative Time,
DCR TestingSupport Custom Access Point And Count The DCR
CycleLoop Measure Range1~65535 times
Max Steps Per Loop254
Nested LoopNested loop Function,Max Support 3 Layers
Protective FunctionSoftware  ProtectionPower-down Data Protection
•   Off-line Testing Function
Setting Protection Condition,Setting Parameter:Low Voltage limit,Upper Voltage limit,Low Current limit,Upper Current limit,Delay Time
Hardware ProtectionAdditional Anti-reverse Protection Model
Voltage and Current Testing Sample4-wire connecting
Noise  Density<85dB
Data  ManagementMYSQL
Communication  MeansTCP/IP Protocol
Data OutputEXCEL,TXT
Communication  InterfaceEthernet Port
No. Of  Channels Per Unit4
Equipment Working Environment
Project indexParameter index
Working  Temperature0℃- 40℃
Storage   Temperature-10℃- 50℃
Working  Humidity≤70%RH
Storage   Humidity≤80%RH