Products Description
- XW-CT-4008-5V5mA Button Cell Tester is an eight-channel battery analyzer for analyzing small button cell batteries with a range of current from 0.025-5mah and voltage from 0-5v. Each channel of the analyzer has an independent constant current source and constant voltage source, which can be programmed and controlled by computer software.
2.The button cell tester provides most applications in the field of battery testing, such as electrode material research, battery performance testing, small scale battery formation, capacity grading, battery pack testing, etc.
The button battery tester is suitable for all kinds of button batteries, such as lithium batteries, nickel-metal hydride batteries, zinc-manganese watch batteries and so on.
Technical Parameters
Project index | Parameter index | |
Input Power | AC 110V/220V ±10% 50Hz/60Hz | |
resolution | AD:16bit;DA:16bit | |
Input Resistance | ≥10 GΩ | |
Input Power | 354mW | |
Channel Features | Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure | |
Channel Control Mode | Independent Control | |
Voltage | Constant Voltage Range | 25mV~5V |
Discharge Min Voltage | 0V | |
Accuracy | ± 0.05% of FS | |
Stability | ± 0.05% of FS | |
Current | Per Channel Current Range | 0.025mA-5mA |
Accuracy | ± 0.05% of FS | |
Stability | ± 0.05% of FS | |
Power | Per Channel Output Power | 0.025W |
Stability | ± 0.1% of FS | |
Time | Current Response Time | 1ms (0-Full Range) |
Step Time Range | ≤(365*24 )hour/step, | |
Time Form Support 00:00:00(h、min:s、ms) | ||
Data Recording | Record Condition | Minimum Time Interval: 100ms |
Minimum Voltage Interval: 10mV | ||
Minimum Current Interval : 0.01mA | ||
Record Frequency | 10Hz | |
Charge | Charge Mode | Constant Current Charge、Constant Voltage Charge、 |
Constant Current and Constant Voltage Charge、CPC | ||
End Conditon | Voltage、Current、Relative Time、Capacity | |
Discharge | Discharge Mode | CCD、CPD、CRD |
End Condition | Voltage、Current、Relative Time、Capacity、 | |
Pulse | charge | CCC, CPC |
Discharge | CCD, CPC | |
Min Pulse Width | 500ms | |
Automated Switch | Automated swith from charge to discharge for each pulse | |
End Condition | Voltage, Test Time | |
Cycle | Loop Measure Range | 1~65535 times |
Max Steps Per Loop | 254 | |
Nested Loop | Nested loop Function,Max Support 3 Layers | |
Protection | Software Protection | l Power-down Data Protection |
l Off-line Testing Function | ||
l Setting Protection Condition,Setting Parameter:Low Voltage limit、Upper Voltage limit、Low Current limit、Upper Current limit、Delay Time | ||
Hardware Protection | Additional Anti-reverse Protection Model | |
DCIR testing | Support | |
Voltage and Current Testing Sample | 4-wire connecting | |
Noise | <85dB | |
Database | MySQL Database | |
A Means of Communication of Upper Machine | TCP/IP Protocol | |
Data Output | EXCEL、TXT、Graph | |
Communication Interface | Ethernet Port | |
Per Unit Main Channels No. | 8 | |
Dimensions | 250*200*60(mm) |