Products Description
Applicable to discharge test and capacity recording of lithium battery packs in power tools, solar energy storage, twisting cars, scooters, electric bicycles, electric motorcycles, etc.
>Discharge function:with constant current discharge function.
Check voltage protection: By discharging the battery, you can detect whether the battery’s discharge protection is working.
Record discharge capacity: discharge the battery and save the displayed discharge capacity.
>Continuous test function: continuous test function after power failure.
Safety protection: anti reverse connection protection function; safe discharge current protection (maximum current 50A).
Function introduction
- Discharge function: It has constant current discharge function;
- Check voltage protection: By discharging the battery, it can be detected whether the discharge protection of the battery is working;
- Record discharge capacity: Discharge the battery and save and display the discharge capacity;
- Safety protection: Anti-reverse connection protection function, safe discharge current protection;
- Continuous measurement function: Power-off continuous measurement function.
Equipment environment requirements and technical parameters:
- Power supply: AC voltage 220V ±10%, frequency: 50Hz±10%;
- Ambient temperature: -10~45℃;
- The environment should not have strong vibrations, corrosive gases, or flammable and explosive gases.
Technical Parameters
Model | BDS 100-20 | BDS 100-30 | |
Input power supply | AC220V ±10%/50Hz | ||
Voltage | Measuring range | 0-100V | |
Accuracy | ±(0.2% of reading + 0.2% of range) | ||
Current | Charging range | 0-20000mA | 0-50000mA |
Accuracy | ±(0.2% of reading + 0.2% of range) | ||
Capacity | Accuracy | ±1‰ | |
Power | Discharge power | ≤1000W | ≤3000W |
Time | Patrol inspection time | Receive real-time<2S | |
Timing range | 0-999 hours/work step | ||
Data recording interval | ≥2S | ||
Median version | 1.1 Series | ||
Discharge | Discharge mode | Constant current discharge | |
Closing conditions | Voltage, relative time, over discharge protection | ||
Chassis size | 430*210*210mm(W*D*H) | 700*450*170mm(W*D*H) |