Products Description
It is widely used in the production and scientific research and experimental testing of power battery packs such as automotive electronics, aerospace, shipbuilding, solar energy storage, electric bicycles, electric motorcycles, backup power batteries, communication power supplies, etc.
Advantageous functions:
- Supports lithium battery pack solutions for the same port, different ports, hardware boards and software boards
- Friendly human-computer interaction interface, supports online use of multiple machines, improves efficiency and production capacity
- Supports barcode scanning for automatic start/manual start, can generate data tables for storage, and facilitates product traceability
- Automatically records test results, supports saving to database or file Excel, and uploads to MES
- Supports serial port and host computer software communication, self-equipped computer
Test function:
- Open circuit voltage test AC internal resistance test Charge and discharge overcurrent delay;
- Continuous charge and discharge test NTC, ID resistance test;
- Battery PACK continuous charging function, verify whether the charging is normal;
- Battery PACK continuous load capacity, continuous discharge to check voltage drop ΔV.
Software part: Personal computer software: runs on the computer, coordinates and controls the entire test system, completes data collection and collation, and generates test reports. The test software system has independent intellectual property rights, and the software system is fully functional. It determines the pass/fail of the test results according to the user-defined specifications; the test system locally saves all test result information in the form of Excel files.
Technical Parameters
Test Item | Test items | Test range | Resolution | |
Open circuit voltage | Open circuit voltage 1 | 0-50V | 2mV | |
Open circuit voltage 2 | 0-50V | 2mV | ||
AC internal resistance | AC internal resistance test | 0-1000mΩ | 1mΩ | |
Discharge test | Start voltage | 0-50V | 2mV | |
End voltage | 0-50V | 2mV | ||
Discharge current | 0.1-60A | 1mA | ||
Discharge time | 0-60S | 1mS | ||
Discharge overcurrent test | Over discharge current | 4-60A | 1mA | |
Over current delay | 0-20S | 1mS | ||
Charging test | Start voltage | 0-50V | 2mV | |
End voltage | 0-50V | 2mV | ||
Charge current | 0.1-5A | 1mA | ||
Charge time | 0-60S | 1mS | ||
Charging protection test | Charge over current | 2-5A | 1mA | |
Charge delay | 0-20S | 0.1mS | ||
Resistors R1/R2 | NTC、ID | 0-1000KΩ | 0.1KΩ | |
Sustainable output power | 0.25kW | |||
Sustainable load power | 3kW | |||
Online mode | USB-R5232 serial communication (can be used with multiple units) | |||
Test data | Generate data table and save automatically, can export to Excel | |||
Barcode management | Support barcode startup and bind test data | |||
Warranty period | 1 year | |||
Free software upgrade service | Lifetime free upgrade until hardware incompatibility | |||
Heat dissipation | Rely on ventilation system, forced air cooling |