Xiaowei

Four Workstation Glove Box For Lithium Battery

Battery Process

More Custom Items

Four Workstation Glove Box For Lithium Battery

Item No.: XW–GB-4880-S
Application:

The inert gas in the glove box is closed circulation by the circulation fan and purifier. H2O, O2 can be removed continuously.

Auto Purging – The replacement of the atmosphere inside the glove box can be achieved

Order(MOQ): 1 set;
Payment: T/T, Western Union, Paypal, L/C;
Product Origin: China;
Lead Time: 15days;
Note: XIAOWEI factory supports OEM.

 Products Description 

The glove box operates with a closed-loop inert gas system, facilitated by a circulation fan and purifier, which continuously eliminates H2O and O2.
Auto Purging – The internal atmosphere of the glove box is automatica7lly refreshed through purging valves.
Automatic Regeneration – The materials responsible for removing H2O and O2 can be regenerated, with the entire process managed by a programmed system.
Pressure Control in the Glove Box – The internal pressure is regulated automatically via a Programmable Logic Controller (PLC), allowing the working pressure to be adjusted between +10mbar and -10mbar. The system includes an automatic protection feature that activates if the pressure exceeds +/-12mbar.
Automatic Vacuum Pump Control – The vacuum pump is designed to activate automatically as needed and will shut down after a predetermined period of inactivity.

 Technical Parameters 

ItemParameter
Glove BoxDimensions:4880mm wide x 750mm deep x 900mm high,.
Innersurface: stainless steel
Outer surface: spray paint, white
Material for Box:3mm thick. 304 stainless steel, acid resistant
Windows -Slanted window, transparent tempered safety glass, thickness 8 mm, protective film.
Glove Ports –Material is hard aluminum alloy, O-ring seal.
Gloves – Butyl – 8” cuff diameter -0.4” Thick – 32” Length
Dust Filter – 0.3 µm – 1 gas inlet and 1 gas outlet filter
Shelves – Stainless -adjustable height.
External Fluorescent Lights -LED lights, mounted in front of each glass window
Interface: 16 spare interfaces, DN 40 KF.
Main AntechamberLarge Antechamber – 304 Stainless Steel
360mm(14.2”)Diam. – 600mm(23.6”) Long (R or L)
Surface: the inner surface is polished and the outer surface is painted (white)
Sliding Tray on Stainless304
Door: double door, anodized aluminum material, thickness 10mm, vertical operation, with lifting mechanism
Pressure gauge: analog display
Control:Solenoid valve touch screen automatic operation
Mini AntechamberOne – Mini Antechamber – 304 Stainless Steel
150mm(5.9”) Diam. – 300mm(11.8”) Long (R or L)
Surface: the inner surface is brushed and the outer surface is painted (white)
Door: double door with moving sliding plate, press-button opening method
Pressure gauge: analog display
Manual Operation via Hand Valve
Gas PurificationFunction:Removal of H2O and O2.
Container material: 304 stainless steel.
Purification material: copper catalyst: 9 kg; molecular sieve: 9kg
Purification capacity: oxygen removal: 100L; water removal: 4Kg
Water oxygen index: less than 1ppm
Circulatory systemWorking gas: nitrogen, argon, helium
Cycle capacity: integrated fan flow 145m3 / h
RegenerationOperation: PLC automatically controls the regeneration process.
Regeneration gas: mixed gas of working gas and hydrogen, (hydrogen 5-10%)
ValveMain valve: DN 40 KF, electric dynamic angle valve
Control valve: electromagnetic integrated valve
 Control SystemFunction: including self-diagnosis, power-off self-starting feature, pressure control and adaptive function; automatic control, cycle control, password protection; unit control adopts Siemens PLC touch screen.
Pressure control: The pressure working pressure of the control box and transition chamber can be set freely within +/- 10 mbar, and the automatic protection is beyond +/- 12 mbar.
Pedal: Controls the pressure of the cabinet for easy operation and step-down.
PLC (Programmable Logic Controller).
Vacuum PumpSpecification: 12m3 / h, rotary vane pump, with oil mist filter, gas vibration control.
Display systemUsing Siemens PLC touch screen smart 700, display operating status, cabinet pressure, system records, etc.
Vacuum system control situationBritish EDWARDS vacuum pump, can be started manually or through PLC, flow rate 12m3 / h, can vacuum the transition chamber, and maintain the tank pressure balance, vacuum pump limit vacuum≤2×10-1pa
Oxygen analyzerMeasuring range: 0 ~ 1000ppm
The ZrO2 sensor avoids the problem that the fuel cell has a short life and cannot be exposed to the air
Water analyzerMeasuring range: 0~500ppm platinum electrode structure (P2O5 structure, which can be cleaned to the factory level by simple cleaning). Wide range of applications, especially for lithium battery manufacturing and metal organic users, can restore the initial state through the cleaning regeneration program.
Avoid the problem of scrapping once a pollution.
Increase the organic solvent adsorberDimensions: diameter 238mm, height 407mm, material 3mm thick 304 stainless steel. Installed on the circulation line.

No tags found for this equipment.

SEND A MESSAGE

If you have any questions during new energy battery production, you can contact xiaowei at any time and xiaowei will give us professional answers.