Xiaowei

Hinge Front Window Vacuum Flange Glove Box

Battery Process

More Custom Items

Hinge Front Window Vacuum Flange Glove Box

Item No.: XW–GB-1220-N-KS
Application: This is a vacuum flange glove box with single station, single operation, integrated with a single column purification unit, PLC touch screen operation control, vacuum pump, bracket, a closed box, with operating surface tilt and safety glass quick-opening hinge front window.
Order(MOQ): 1 set;
Payment: T/T, Western Union, Paypal, L/C;
Product Origin: China;
Lead Time: 15days;
Note: XIAOWEI factory supports OEM.

 Products Description 

This is a single-station vacuum flange glove box system designed for individual operations. It features an integrated single-column purification unit and is equipped with a PLC touch screen for operational control. The system includes a vacuum pump, a sturdy bracket, and a sealed enclosure. The workstation is ergonomically designed with a tilted operating surface and a front window that incorporates safety glass with a quick-release hinge mechanism.

Operating under standard conditions—maintained at a constant temperature of 20℃ and at standard atmospheric pressure—the glove box ensures a high-purity environment. It utilizes inert gas with a purity level of 99.999%, maintaining strict control over contaminants with water and oxygen levels kept below 0.1 ppm. This setup is ideal for sensitive processes requiring stringent environmental controls.

 Technical Parameters 

Function:
* Closed re-circulation
The inert gas in the glove box is continuously deoxygenated and dehydrated through the closed circulation of the circulating fan and purifier
*Automatic control regeneration
Water and oxygen removal materials can be regenerated, and the regeneration process is controlled by the program
* Automatic cleaning
Atmosphere replacement in the glove box through Automatically controlled cleaning valve
*Box pressure control
The box pressure through the PLC auto control, working pressure +/- 15mbar can be set, Beyond +/- 16mbar system automatic protection.
* Vacuum pump auto control
The vacuum pump will open auto when system need
Basic configuration:
304 stainless steel box, acid-resisting, thickness: 3mm1 set
Stainless steel vacuum transitional chamber, φ360*600mm, right side1
Small stainless steel transitional chamber,φ150*300mm., right side1
Hinge front window with 2 glove ports.1
Butyl rubber gloves.1 pair
Lighting system1 set
High-performance circulating fan with frequency conversion1 set
PLC control and touch screen control operating system1 set
Purification system1 set
Vacuum pump1 set
Oxygen analyzer1 set
Water analyzer1 set
Quick change organic solvent adsorber1 set
Power interface inside the box1
Blind flange4 pcs
Bracket and trundle1 set
Foot pedal1 pcs
Technology parameters
ItemParameter
Main parameterWater/ oxygen index: Less than 0.1ppm
Leakage rate : 0.001vol%/h
Glove boxBoxBox size: (L*W*H)=1220×750×900mm
Box material: stainless steel 304, thickness 3mm
Inner surface: stainless steel wire drawing treatment
Outside surface: paint, white
Front windowQuick-opening hinge front window, Tilt windows, transparent tempered safety glass, thickness 8 mm
The glass window adopts a solid O-ring (vacuum sealing method) flange window structure.
Glove portsThe material is polyoxymethylene, O-ring seal, self-lubricating performance, easy to maintain, and good sealing performance
GlovesButyl rubber, thickness 0.4mm, diameter 8″, length 32″
Filter:0.3 microns, a gas inlet and a gas outlet
ShelfStainless steel, 2-3Layers
LightingLED lights, installed in front of each glass window
ConnectorStandby interface 4pcs, DN 40 KF, Power interface 1pc (220V)
Bigger antechamberChamberSize: diameter 360mm, length 600mm
Material: 304 stainless steel
Surface: inner surface wire drawing process, outer surface painting (white)
AccessorySliding tray: 304 stainless steel
Door: double door, anodized aluminum material, thickness 10mm, vertical operation, with lifting mechanism
Pressure gauge: Analog display
ControlSolenoid valve touch screen automatic operation
Smaller antechamberChamberSize: diameter 150mm, length 300mm (100mm length into the glove box)
Material: 304 stainless steel
Surface: inner: wire drawing process, outer: painting (white)
AccessoryStandard configuration: small cabin tray
Door: double door, thread lock
Pressure gauge: Analog display
ControlManual valve manual operation
Gas purification circulation systemPurification columnFunction: gas sealed, remove water, remove oxygen
Container material: 304 stainless steel
Purification materials: copper catalyst: 5kg, molecular sieve: 5 kg
Purification capacity: oxygen: 60L, water: 2Kg
Water and oxygen indicators: less than 1ppm
Circulatory systemWorking gas: nitrogen, argon,helium
Recycling capacity: integrated fan flow 90m³ / h, install frequency conversion
RegenerationOperation: PLC automatically controls the regeneration process
Regeneration gas: working gas mixed with hydrogen gas, (hydrogen 5-10%)
Vacuum pump12m³ / h, rotary vane pump, with oil mist filter, air vibration control
ValvesMain valve: DN 40 KF, electrically operated angle valve
Control valve: electromagnetic integrated valve
Control SystemFunctionIncluding self-diagnosis, power-off self-starting characteristics, with pressure control and adaptive function
Automatic control, cycle control, password protection
Pressure controlPLC Auto control, cabinet working pressure +/- 15mbar can be set freely, beyond +/- 16mbar system automatic protection
PedalControl the box pressure, easy to operate boost and buck
Display systemUsing Siemens PLC touch screen, display running status, box pressure, system records etc
Vacuum system controlVacuum pump, can be manually or through the PLC to start, flow 12m³/h, vacuum of the transition chamber, and keep the box pressure balance, vacuum pump limit vacuum ≤ 2×10-1pa
 BasicWater analyzerMeasuring range: 0~500ppm platinum electrode structure (P2O5 structure, can reach the factory level by simple cleaning), a wide range of applications, especially for users such as lithium battery manufacturing and metal organic, can be restored to the initial state through the cleaning and regeneration process, avoiding one-time pollution and scrapping The problem.
componentsOxygen analyzerMeasuring range: 0 ~ 1000ppm
The use of ZrO2 sensor, to avoid the fuel cell life is short, and avoid the problem of it can not be exposed in the air
Quick change organic solvent adsorberSize: diameter 238mm, height 407mm, 3mm thickness304 stainless steel Filled with 10kg of activated carbon. Connected with the main circulation pipeline, the circulating gas can first flow through the organic solvent adsorb-er device to absorb the organic solvent in the gas. Quick and convenient replacement of adsorbent materials. After replacing the activated carbon, the adsorption column can be vacuumed to eliminate air and avoid contaminating the high-purity atmosphere inside the box.
Installation Requirements (Customer Provided):
1. Two cylinders of pure argon (nitrogen or helium are acceptable alternatives) with a minimum purity of 99.99%.
2. One cylinder of ultra-high purity argon (nitrogen or helium are acceptable alternatives) with a minimum purity of 99.999%.
3. One cylinder of argon-hydrogen mixture (nitrogen-hydrogen or helium-hydrogen mixtures are acceptable alternatives)

No tags found for this equipment.

SEND A MESSAGE

If you have any questions during new energy battery production, you can contact xiaowei at any time and xiaowei will give us professional answers.