Xiaowei

Lab Glove Box

Battery Process

More Custom Items

Lab Glove Box

Item No.: XW-GB-800S
Application:Lab glove box is a kind of equipment with anhydrous and anaerobic environment.
Order(MOQ): 1 set;
Payment: T/T, Western Union, Paypal, L/C;
Product Origin: China;
Lead Time: 15days;
Note: XIAOWEI factory supports OEM.

 Products Description 

The Super Model (1220/750/900) is a single-station, single-operation system integrated with a purification unit featuring a single column. It is equipped with a PLC touch screen for operation control, a vacuum pump, a bracket, and a closed box. The system includes an operating surface that can tilt and a detachable safety glass front window. It operates under standard conditions: a constant temperature of 20℃, standard atmospheric pressure, inert gas purity of 99.999%, and water and oxygen levels below 1 ppm.

 Technical Parameters 

2.  Basic configuration
* 1 set 304 stainless steel box, acid-resisting, thickness : 3mm                                                                                    
* 1 stainless steel vacuum transitional chamber, φ360*600mm
* 1 small stainless steel transitional chamber,φ150*300mm.
* 1 front window with 2 glove ports.
* 1 pairs of butyl rubber gloves.
* 1 set of lighting system
* 1 power interface inside the box
* 1 set of high-performance circulating fan
* 1 set of purification system
* 1 vacuum pump
* 1 set of PLC control and touch screen operating system
* 4 pcs blind flange
* 1 set of water analyzer
* 1 set of oxygen analyzer
* 1 bracket and trundle
* 1 foot pedal
ItemParameter
Glove boxBoxBox size: (L*W*H)=1220×750×900mm
Box material: stainless steel 304, thickness 3mm
Inner surface:Stainless steel oil film drawing treatment
Outside surface: paint, white
Front windowTilt windows, transparent tempered safety glass, thickness 8 mm
Glove portsThe material isaluminum, O-ring seal, self-lubricating performance, easy to maintain, and good sealing performance
GlovesButyl rubber, diameter 8″, length 32″, thickness≥0.4mm
Filter:0.3 microns, a gas inlet and a gas outlet
ShelfStainless steel, 2 layers, height adjustable
LightingLED lights, installed in front of each glass window
ConnectorStandby interface 3pcs, DN 40 KF, Power interface 1pc (220V)
BiggerAntechamberChamberSize: diameter 360mm, length 600mm
Material: 304 stainless steel
AccessorySliding tray: 304 stainless steel
Door: double door, anodized alumina material, thickness 10mm, vertical operation, with lifting mechanism
Pressure gauge: Analog display
ControlSolenoid valve touch screen automatic operation
SmallerAntechamberChamberSize: diameter 150mm, length 300mm (100mm length into the glove box)
Material: 304 stainless steel
Surface: inner: wireoil filmdrawingtreatment, outer: painting (white)
AccessoryTray:304 stainless steel
Door: double door,Button flip
Pressure gauge: Analog display
ControlSolenoid valve touch screen automatic operation
 Gas purification circulation system

(Independent purification caibinet)
Purification columnFunction: gas sealed, remove water, remove oxygen
Container material: 304 stainless steel
Purification materials: copper catalyst: 5kg, molecular sieve: 5 kg
Purification capacity: oxygen: 60L, water: 2Kg
Water and oxygen indicators: less than 1ppm
Circulatory systemWorking gas: nitrogen, argon
Recycling capacity: integrated fan flow 90m³ / h, install frequency conversion
RegenerationOperation: PLC automatically controls the regeneration process
Regeneration gas: working gas mixed with hydrogen gas, (hydrogen 5-10%)
Vacuum pump8m³ / h, rotary vane pump, with oil mist filter, air vibration control
ValvesMain valve: DN 40 KF, electrically operated angle valve
Control valve: electromagnetic integrated valve (stainless steel integrated valve base, single column for the six valve integration)
Control SystemFunctionIncluding self-diagnosis, power-off self-starting characteristics, with pressure control and adaptive function
Automatic control, cycle control, password protection, calculator,
The unit is controlled by Siemens PLC touch screen. The touch screen is locked with a password. It is automatically locked after five minutes of unattended operation. You need to re-enter the password next time you enter the operation interface.
Pressure controlAutomatically control the pressure of the cabinet and transition cabin through PLC, cabinet working pressure +/- 10mbar can be set freely, beyond +/- 12mbar system automatic protection
PedalControl the box pressure, easy to operate boost and buck
Information memorandumAutomatic recording of system data
Display systemUsing Siemens PLC touch screen, display running status, box pressure, system records etc.
The touch screen is locked with a password. It is automatically locked after five minutes of unattended operation. You need to re-enter the password next time you enter the operation interface.
Vacuum system controlVacuum pump, can be manually or through the PLC to start, flow 8m³/h, vacuum of the transition chamber, and keep the box pressure balance, vacuum pump limit vacuum ≤ 2×10-1pa
Water analyzerMeasuring range: 0 ~ 500ppm
A wide range of applications, especially for lithium manufacturing and metal organic and other users, the water probe can be cleaned by the regeneration process to restore the initial state, can be reused
Oxygen analyzerMeasuring range: 0 ~ 1000ppm
The use of ZrO2 sensor, to avoid the fuel cell life is short, and avoid the problem of it can not be exposed in the air
Organic solvent adsorberSize: diameter 136mm, height 256mm, filled with 2kg activated carbon, placed inside the box, can quickly replace the material

No tags found for this equipment.

SEND A MESSAGE

If you have any questions during new energy battery production, you can contact xiaowei at any time and xiaowei will give us professional answers.