Xiaowei

Single & Double Channel Programmable DC Electronic Load Battery Load Tester

Battery Process

More Custom Items

Single & Double Channel Programmable DC Electronic Load Battery Load Tester

Item No.: XW-ET53 series
Application: XW-ET53 series DC programmable electronic load provides 1mV/10mV, 1mA/10mA high resolution and precision with superior performance.
Order(MOQ): 1 set;
Payment: T/T, Western Union, Paypal, L/C;
Product Origin: China;
Lead Time: 15days;
Note: XIAOWEI factory supports OEM.

 Products Description 

The XW-ET53 series DC programmable electronic load provides high resolution and accuracy of 1mV/10mV and 1mA/10mA, with superior performance and 12 commonly used modes. It has complete testing functions and can be widely used in production line testing of chargers, switching power supplies, linear power supplies, batteries, etc.

 Technical Parameters 

General technical specifications:
Power supply voltage: 220Vac±10%, 110Vac±10%, 45-65Hz
Display: 3.5-inch TFT LCD screen with resolution of 480×320
Operating temperature: 0℃ to 40℃
Storage temperature: -10℃ to 70℃
Relative humidity: < 80%
Interface: standard USB, RS232 or 485(optional)
Size: 320mm×220mm×100mm (width × height × depth) 
Key Features:
User-friendly Design: 
It adopts 3.5-inch TFT LCD screen with rich display contents and supports Chinese and English display;
The operation process is simple and convenient, and with visual interface display system, it is easy to get started.
Key lock function to prevent misoperation;
High-performance load:
It provides CC, CV, CR, CP and CC+CV, CR+CV several basic measurement modes;
It provides professional battery test;
It provides professional LED test;
The Tran test mode can test the dynamic output performance of the power supply;
The scan test mode can test the continuity of power output within a certain range;
Support 4-wire measurement;
The list test mode can simulate a variety of loading status changes;
The short circuit test can be used to simulate load short circuit;
Support external trigger input;
Built-in buzzer alarm;
Maintain data storage in case of power failure;
Remote operation via USB, RS-232or 485 (optional) interfaces;
Multiple safety protection:
It provides overcurrent, overvoltage, overpower, over temperature protection. The overvoltage and overcurrent parameters can be set flexibly, so as to effectively protect the load;
It has intelligent fan speed control function, which can effectively reduce the fan noise when it is working.
With input polarity reverse prompt;
XW-ET5300AXW-ET5300XW-ET5301XW-ET5302XW-ET5303XW-ET5304
Single channelSingle channelSingle channelSingle channelSingle channelDual channel
Power200W400W400W400W400W400W(200W*2)
Input voltage150V150V150V500V500V150V
Input current30A40A60A15A30A60A(30A*2)
ModelXW-ET5300AXW-ET5300XW-ET5301
Rated inputPower200W400W
Input voltage0-150V
Input current0-30A0-40A0-60A
CV modeRange0.1~19.999V,0.1~150.00V
Resolution1mV,10mV
Accuracy±(0.05%+0.02%FS)
CC modeRange0~3.000A0~6.000A
0~30.00A0~40.00A0~60.00A
Resolution1mA,10mA
Accuracy±(0.05%+0.05%FS)
CR modeRange0.05Ω~1 kΩ,1 kΩ~4.5kΩ
Resolution10mΩ,100mΩ
Accuracy±(0.1%+0.5%FS)
CP modeRange0~200W0~400W
Resolution10mW
Accuracy±(0.1%+0.5%FS)
Tran TestModeCC,CV
T1&T250ms~60s;
Battery TestAccuracyCC,CR
Discharge mode9999Ah
Maximum discharge capacity1mA,10mA,10mΩ,100mΩ
Range of measurement
Voltage read-back valueRange0~19.999V,0 ~150.00V
Resolution1mV,10mV
Accuracy±(0.05%+0.1%FS)
Current read-back valueRange0~3.000A0~6.000A
0~30.00A0~40.00A0~60.00A
Resolution1mA,10mA
Accuracy±(0.05%+0.1%FS)
Power read-back valueRange200W400W
Resolution10mW
Accuracy±(0.1%+0.5%FS)
Scope of protection
Overvoltage protection>21V or 155Vovervoltage protection
Overcurrent protection>3.1A or 31A input cut off>3.1A or 41A input cut off>6.1A or 61A input cut off
Overpower protection210W410W
Over-temperature protection85℃
ModelXW-ET5302XW-ET5303XW-ET5304
Rated inputPower400W400W(200W*2)
Input voltage0-500V0-150V
Input current0-15A0-30A0-60A(30A*2)
CV modeRange0.1~19.999V,0.1~500.00V0.1~19.999V,0.1~150.00V
Resolution1mV,10mV1mV,10mV
Accuracy±(0.05%+0.02%FS)±(0.05%+0.02%FS)
CC modeRange0~3.000A,0~15.00A0~3.000A,0~30.00A0.1~19.999V,0.1~150.00V
Resolution1mA,10mA1mV,10mV
Accuracy±(0.05%+0.05%FS)±(0.05%+0.02%FS)
CR modeRange0.05Ω~1 kΩ,1 kΩ~4.5kΩ0.05Ω~1 kΩ,
1 kΩ~4.5kΩ
Resolution10mΩ,100mΩ10mΩ,100mΩ
Accuracy±(0.1%+0.5%FS)±(0.1%+0.5%FS)
CP modeRange0~400W0~200W
Resolution10mW10mW
Accuracy±(0.1%+0.5%FS)±(0.1%+0.5%FS)
Tran TestModeCC,CVCC,CV
T1&T250ms~60s;50ms~60s;
Battery TestAccuracyCC,CRCC,CR
Discharge mode9999Ah9999Ah
Maximum discharge capacity1mA,10mA,10mΩ,100mΩ1mA,10mA,
10mΩ,100mΩ
Range of measurement
Voltage read-back valueRange0~19.999V,0 ~500.00V0~19.999V,0 ~150.00V
Resolution1mV,10mV1mV,10mV
Accuracy±(0.05%+0.1%FS)±(0.05%+0.1%FS)
Current read-back valueRange0~3.000A,0~15.00A0~3.00A,0~30.00A0~3.000A,0~30.00A
Resolution1mA,10mA1mA,10mA
Accuracy±(0.05%+0.1%FS)±(0.05%+0.1%FS)
Power read-back valueRange400W200W
Resolution10mW10mW
Accuracy±(0.1%+0.5%FS)±(0.1%+0.5%FS)
Scope of protection
Overvoltage protection>21V or 510Vovervoltage protection>21V or 155Vovervoltage protection
Overcurrent protection>3.1A or 16A input cut off>3.1A or 31A input cut off>3.1A or 31A input cut off
Overpower protection410W210W
Over-temperature protection85℃85℃

No tags found for this equipment.

SEND A MESSAGE

If you have any questions during new energy battery production, you can contact xiaowei at any time and xiaowei will give us professional answers.