Gas Adsorption Analyzer – Technical Specifications
Power Supply
Voltage: 100V~220V ± 10V

Frequency: 50/60Hz

Maximum Power Consumption: 300W

Connection: Grounded single-phase power socket

Physical Properties
Dimensions:

Length: 60 cm (23.6 inches)

Width: 48 cm (18.9 inches)

Height: 74 cm (29.1 inches)

Net Weight: 60 kg (132.3 lbs)

Accessories Weight: 30 kg (66.1 lbs)

Recommended Installation Area (L × W): 100 × 60 cm (excluding additional space for computer setup)

Functional Capabilities
Surface Area Measurement
BET surface area (single-point and multi-point)

Langmuir surface area

T-plot method:

External surface area

Total microporous surface area

BJH method:

Adsorption and desorption cumulative surface area

Pore Volume Determination
Single-point total pore volume

BJH adsorption/desorption cumulative pore volume

T-plot micropore volume

Average Pore Size Measurement
Adsorption average pore diameter

BJH adsorption/desorption average pore diameter

Most frequent pore diameter

Pore Size Distribution
BJH differential pore distribution: dV/Dr–D, dV/dlogD–D

BJH integral (cumulative) distribution

MP method micropore distribution

 Technical Parameters

Technical Parameters
Test Principle: Static volumetric gas adsorption method

Analysis Models: BET, Langmuir, BJH, T-Plot, DR, MP, NLDFT

Measurement Range:

Surface Area: ≥ 0.005 m²/g (no upper limit)

Pore Size: 2–500 nm

Pore Volume: ≥ 0.0001 cc/g (no upper limit)

Test Gases: High-purity N₂ (default); Optional: Ar, Kr, CO₂, etc.

Analysis Ports: 2 independent analysis ports

Degassing Stations: 2

Sample Types: Powders, granules, fibers, flakes, and other materials

Sensors: Two high-precision pressure sensors (0–1000 Torr / 0–133 kPa)

Test Efficiency:

Multi-point BET surface area: ~12 min/sample

Pore size distribution (adsorption only): ~1.5 hrs/sample

Pore size distribution (adsorption & desorption): ~3.5 hrs/sample

Partial Pressure Range (P/Po): 4 × 10⁻⁵ to 0.998

Minimum Resolvable Relative Pressure: 5 × 10⁻⁵

Ultimate Vacuum: 4.0 × 10⁻² Pa (3 × 10⁻⁴ Torr)

Pressure Accuracy: ≤ ±0.15% Full Scale

Repeatability:

Surface Area: ≤ ±1.0%

Pore Size: ≤ 2 nm

Operation Mode: Fully automatic