Products Description
1.XW-5V10mA Button Cell Tester is an eight-channel battery analyzer for analyzing small button cell batteries with a current range of 0-10mah and a voltage range of 0-5v. Each channel of the analyzer has an independent constant-current and constant-voltage source, which can be programmed and controlled by computer software
2.This button cell tester is suitable for most applications in the battery testing field, such as electrode material research, battery performance testing, small scale battery chemistry, capacity grading, battery pack testing, etc
3.The button battery tester is suitable for all kinds of button batteries, such as lithium batteries, nickel-metal hydride batteries, zinc-manganese watch batteries and so on.
Technical Parameters
Model | XW-CT-4008-5V10mA-164 | |
Voltage | AC 220V ±10%, 50Hz | |
Resolution | AD: 16bit DA: 16bit | |
Input Resistance | ≥1 GΩ | |
Input Power | 25W | |
Voltage | Constant Voltage Range | 25mV-5V |
Discharge Min Voltage | -5V | |
Accuracy | ± 0.05% of FS | |
Stability | ± 0.05% of FS | |
Current | Per Channel Current Range | Range 1: 5uA-1mA, Range 2: 1mA-5mA, Range 3: 5mA-10mA |
Accuracy | ± 0.05% of FS | |
Constant voltage cutoff current | Range 1: 2uA, Range 2: 0.01mA, Range: 0.02mA | |
Stability | ± 0.05% of FS | |
Power | Per Channel Output Power | 0.05W |
Stability | ± 0.1% of FS | |
Time | Current Response Time | <500us (10%FS-90%FS) |
Step Time Range | ≤(365*24 )hour/step, | |
Time Form Support 00 : 00 : 00 : 00 (h min s ms) | ||
Data Recording | Record Condition | Minimum Time Interval: 100ms |
Minimum Voltage Interval: 10mV | ||
Minimum Current Interval | ||
Range 1: 2uA, Range 2: 0.01mA, Range 3: 0.02mA | ||
Record Frequency | 10Hz | |
Charge | Charge Mode | Constant Current Charge, Constant Voltage Charge, Constant Current and Constant Voltage Charge, CPC |
End Conditon | Voltage, current, relative time, capacity, -△V | |
Discharge | Discharge Mode | CCD, CPD, CRD, CVD, Constant Current and Constant Voltage Discharge |
End Condition | Voltage, Current, Relative Time, Capacity, -△V | |
Pulse | Charge | CCC, CPC |
Discharge | CCD, CPC | |
Min Pulse Width | 500ms | |
Pulse number | A single pulse step supports 32 different pulses | |
Automated Switch | Automated swith from charge to discharge for each pulse | |
End Condition | Voltage, Test Time | |
Cycle | Loop Measure Range | 1~65535 times |
Max Steps Per Loop | 254 | |
Nested Loop | Nested loop Function, Max Support 3 Layers | |
Protection | Software Protection | Power-down Data Protection |
Off-line Testing Function | ||
Setting Protection Condition, Setting Parameter: Low Voltage limit, Upper Voltage limit, Low Current limit, Upper Current limit, Delay Time | ||
Hardware Protection | Additional Anti-reverse Protection Model | |
Channel Features | Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure | |
Channel Control Mode | Independent Control | |
DCIR testing | Support | |
Voltage and Current Testing Sample | 4-wire connecting | |
Noise | <45dB | |
Database | MySQL Database | |
A Means of Communication of Upper Machine | TCP/IP Protocol | |
Data Output | EXCEL、TXT、Graph | |
Communication Interface | Ethernet Port | |
Per Unit Main Channels No. | 8 | |
Dimensions | 483*310*48(mm) |